SECTION 220700 – INSULATION FOR PLUMBING PIPING …

E. Foam insulation materials shall not use CFC or HCFC blowing agents in the manufacturing process. 2.3 CELLULAR GLASS: ncombustible, foamed or cellulated glass with Inorganic, i annealed, rigid, hermetically sealed cells. Factory-applied jacket requirements are specified in "Factory-Applied Jackets…

Read More

Aluminum Roll Jacketing - Insulation Systems, …

Aluminum Roll Jacketing is the premier protective outer surface for mechanical insulation systems, including pipes, vessels, and equipment. It helps protect the insulation and underlying pipe/vessel from physical damage, UV exposure, corrosive environments, and water. JM's Aluminum jacketing (also called cladding) is available in smooth, stucco ...

Read More

New Column: Insulation Finishes - This Month's Topic ...

jackets are made of a durable, attractive, and easy–to–clean material that is typically field–applied over unfaced insulation and most factory–applied jackets where additional protection is necessary. PVC jackets are covered by ASTM Standard Practice C921–10, Types I and II, Grade 4. PVC jackets are available in several thicknesses ...

Read More

EVALINDA JACKET

16. 15. 32-33. Details. Compact nylon and polyester field jacket, garment dyed, water-repellent, padded with ultra-thermal wadding. Zip and concealed press-stud fastening. Four applied pockets. Elasticated cuff with adjustable tab, drawstring at waist and hem. Regular fit.

Read More

DETAILED SPECIFICATION Polyethylene cased jacket for …

b) Insulated pipe joints (buried) Insulated pipe joints shall consist of field foamed in place Hi-Temp polyisocyanurate foam supplied complete with Canusa SuperSeal heat shrink wrap with closure seal, as supplied by Urecon. The heat-shrink sleeves shall overlap the insulation jacket …

Read More

R1214 – KOOLPHEN K PHENOLIC FOAM INSULATION – Caf-Capex

86,90. STANDARD UNIT PRICE PER HEAD INSTALLED ON VERTICAL OR HORIZONTAL VESSEL HEADS USING SINGLE LAYER THICKNESS BASED ON USING 2.2 POUND DENSITY KOOLPHEN® K PHENOLIC FOAM INSULATION CURVED SEGMENTS AND ALL SERVICE JACKET (ASJ), FIELD APPLIED AND SIZED VESSEL OUTSIDE DIAMETER OF 10'1" TO 11'0". 3Q 2017.

Read More

PITTWRAP SS JACKETING - FOAMGLAS® thermal insulation …

Supplemental Instructions for Field-Applied Jacketing STEP 1 STEP 2 After FOAMGLAS ® insulation is installed; Strike a horizontal line along the insulation convenient for starting jacket positioning and to insure a uniform lap line. Cut a length of jacketing to provide at least a 50 mm (2 in.) overlap at the longitudinal seam. STEP 3 STEP 4

Read More

230713 – Duct Insulation - Division 230000

3.6 Installation of Mineral-Fiber Insulation. 3.7 Field-Applied Jacket Installation. 3.8 Fire-Rated Insulation System Installation. 3.9 Finishes. 3.10 Field Quality Control. 3.11 Duct Insulation Schedule, General. Duct Insulation Schedule. 3.12 Indoor Duct and Plenum Insulation …

Read More

InsulSpec - Insulation Systems, Commercial Roofing …

Hi-Lo Temp fiber glass insulation, and needs to be covered with Zeston 2000 insulated fitting covers. C. Zeston PVC Field-Applied jackets: 1. 20 mil (0.5 mm)/30 mil (0.8 mm)/40 mil (1.0 mm) stock thickness. 2. UV Resistant. 3. Joints secured and sealed with Z-Tape. 4. …

Read More

Micro-Lok HP Pipe Insulation Guide - BuildSite

Hi-Lo Temp fiber glass insulation, and needs to be covered with Zeston 2000 insulated fitting covers. C. Zeston PVC Field-Applied jackets: 1. 20 mil (0.5 mm)/30 mil (0.8 mm)/40 mil (1.0 mm) stock thickness. 2. UV Resistant. 3. Joints secured and sealed with Z-T ape. 4. If tacks are used to hold the PVC in place, then

Read More

ELECTRICAL PROPERTIES OF CABLE INSULATION MATERIALS

¾ Determines how good a dielectric is the insulation ¾ • HIGH FIELD • -Partial discharges (corona) ¾ Controls functioning and reliability. How does Polymer Insulation Respond to ... of applied field and local dipole induced field - called INTERNAL FIELD effect Leads to …

Read More

SECTION 230713 - DUCT INSULATION

Field-applied jackets shall comply with ASTM C921, Type I, unless otherwise indicated. A properly sealed FSK jacket, common with most forms of factory-applied jackets for mineral-fiber insulation, complies with vapor-retarder requirements in ASTM C921, Type I. FSK Jacket: Aluminum-foil-face, fiberglass-reinforced scrim with kraft-paper backing.

Read More

SECTION 230716 - HVAC EQUIPMENT INSULATION

Secure laps to adjacent insulation section with ½ inch (13 mm) outward clinching staples, 1 inch (25 mm) oc. Install vapor barrier consisting of vapor barrier acrylic based tape; matching the facing, or factory or field-applied jacket, adhesive, vapor barrier mastic, and sealant at joints, seams, and protrusions.

Read More

Standard Specification for Jackets for Thermal Insulation

1.2 This specification provides material and/or physical requirements for jackets. Guidance in selecting the proper jacket for a given application can be found in Guide C 1423. 1.3 This specification does not cover field applied mastics or barrier coatings and their attendant reinforcements, nor does it cover jackets for buried insulation systems.

Read More

PVC Jacketing and Fittings | Johns Manville

Johns Manville Zeston® 2000 Series Color standard gauge PVC fitting covers are manufactured from high-impact, polyvinyl chloride material designed to provide abuse-resistant protection for insulated …

Read More

SECTION 220719 - PLUMBING PIPING INSULATION

FIELD-APPLIED JACKETS. Insulation jackets in this article are for field application. ASTM C1136, Type I, is for use over insulation on pipes operating at below-ambient temperatures at least part of the time or where a vapor barrier is required. ASTM C1136, Type II, is for use over insulation on pipes operating above-ambient temperatures or ...

Read More

SECTION 230713 - DUCT INSULATION

Field-applied jackets shall comply with ASTM C921, Type I, unless otherwise indicated. A properly sealed FSK jacket, common with most forms of factory-applied jackets for mineral-fiber insulation, complies with vapor-retarder requirements in ASTM C921, Type I. FSK Jacket…

Read More

Aluminum Jacket for Pipe Insulation | Aluminum Pipe Sleeves

This was due to the fact the insulation I used created more bulk at the elbows. If they were applied direct over the pipe it would have been a perfect fit. I used the fab straps to secure the the installation. I found it necessary to use a strap to pul the jackets and elbows snug.

Read More

Underground Pipe Insulation | Preinsulated Pipe ...

The single product is field applied and available for immediate shipment to your job-site, eliminating the long lead-times of fabrication. Contractors offer Gilsulate as an alternate on their bids because "The installed Gilsulate system was 25% of the cost of the specified pre-insulated system."

Read More

Rovanco HDPE Jacketed System - Insulated PEX Pipe

Each length of pre-insulated pipe will be fitted with a watertight mastic end seal at jacket and pipe surfaces. All field cuts will be sealed with a field applied end seal. Insulation of Straight Joints: After welding and testing, all joints shall be insulated …

Read More

Insulation Jacketing Selection Guide: Types, Features ...

Insulation jacketing consists of an oute r covering that is wrapped around tubing or pipe insulation to protect the insulation from moisture, wear and mechanical damage. The jacket also serves to provide support for the insulation and establish the system emissivity and appearance. Insulation jacketing …

Read More

The North Face Ladies Everyday Insulated Jacket | Product ...

Built for mountain and city life, this jacket has fashionable baffles and colorblocking. Designed for everyday use, it will keep you warm and dry when it gets cold and wet. Shell: 50D WindWall™— recycled polyester taffeta shell; durable water-repellent (DWR) finish and lining. Insulation: 150 g Heatseeker™ synthetic insulation.

Read More

ASTM C921 - 10(2015) Standard Practice for Determining the ...

1.3 This practice does not cover field applied mastics or barrier coatings and their attendant reinforcements, nor does it cover jackets for buried insulation systems. 1.4 The values stated in inch-pound units are to be regarded as standard.

Read More

SECTION 2: INSULATION MATERIALS AND PROPERTIES

deterioration. The material is non-combustible and used primarily on hot piping and surfaces. Jacketing is field applied. 2.4.2 MINERAL FIBER a. Glass: Available as flexible blanket, rigid board, pipe covering and other pre-molded shapes. Service temperature range is -40°C to 232°C.

Read More

Insulation Jacketing Information - Insulation Innovation Blog

Insulation Jacketing Information. Insulation jacketing is an outer covering that is wrapped around tubing or pipe insulation to shield the insulation from moisture, wear, and mechanical damage. Insulation jacketing plays a vital role in the productivity and effectiveness of the mechanical insulation. When selecting a jacketing …

Read More

SECTION 230716 - HVAC EQUIPMENT INSULATION

FIELD-APPLIED JACKETS. Insulation jackets in this article are for field application. ASTM C 921, Type I, is for use over insulation on equipment operating at below ambient temperatures at least part of the time or where a vapor barrier is required. ASTM C 921, Type II is for use over insulation on pipes operating above ambient temperatures, or ...

Read More

Mechanical System Insulation - Northwestern University

A. Field-applied jackets shall comply with ASTM C 921, Type I, unless otherwise indicated. B. FSK Jacket: Aluminum-foil-face, fiberglass-reinforced scrim with kraft-paper backing. C. PVC Jacketing and Pre-Formed Fitting Covers: High-impact-resistant, UV-resistant PVC

Read More

Pipe Insulation - PipeInsulation.net

Available with factory-applied jackets or plain for field applied lagging. Acoustical Insulation As a composite assembly it has exceptional sound attenuation properties. 679 Series is suitable for both …